How we calculate
One calculation drives everything on this site: the battery size we suggest, which stations pass, and how long each would last. Here is all of it, so you can check our work.
The calculation
For each appliance: average watts = running watts × duty cycle (the share of time it’s actually running). Add them up for the average load. Then for an outage of H hours:
- Energy needed = average load × H
- Usable energy of a station = rated capacity × efficiency × (1 − reserve)
- Runtime = usable energy ÷ (average load × (1 + margin))
- Battery size to look for = energy needed × (1 + margin) ÷ (efficiency × (1 − reserve))
The battery size we show is rounded up (to the next 10Wh, or 50Wh above 1,000Wh). A station passes the energy check only if its runtime is at least H. That’s mathematically the same statement as “its capacity is at least the size to look for,” so the battery size, the verdict and the runtime can never disagree. An earlier version of this planner applied efficiency twice in the filter; we fixed it, and an automated test now sweeps 540 combinations of load, capacity, efficiency, reserve and hours to confirm the three always agree.
Defaults: reserve 10%, extra margin 0%. You can change both under “Fine-tune the numbers.”
Efficiency depends on the load
A station’s AC inverter loses energy in two ways: a proportional conversion loss, and a roughly constant draw just to stay switched on. So small loads get proportionally less of the battery than large ones. We model:
efficiency = average load ÷ (average load ÷ 0.90 + 12W)
That gives about 43% at 10W, 71% at 40W, 76% at 60W, 82% at 110W and 88% at 380W. We chose it to sit within published independent tests: Outdoor Life measured stations delivering 76–92% of rated capacity at about 380W, and 49–77% at about 34W (where our model gives 68%). Some stations did worse at small loads — Outdoor Life’s figures for the BLUETTI AC180 at about 34W were 40–54% — which our cautious case (53% at 34W) reflects. OutdoorGearLab measured a Jackery Explorer 1000 v2 delivering 910Wh of its 1,070Wh. Real stations differ in their idle draw, which manufacturers rarely publish, so this is an estimate.
- Runtime ranges: the range under each result uses a cautious case (88% conversion, 25W overhead) and an optimistic case (92%, 6W). Verdicts use the middle estimate; “Covers it” means the cautious case also lasts, and “Only just” means only the middle one does.
- DC output: if you tick “Run small devices from DC/USB ports,” only the router, phones, laptop and CPAP move to DC (92% conversion, 2W overhead); everything else stays on the AC inverter, and the two are combined. We warn if the DC devices add up to more than 100W, since many DC and USB-C ports are limited to roughly 100–140W.
- Fixed efficiency: you can switch to a single fixed percentage under “Fine-tune.”
The three checks
- Battery energy — runtime at least as long as the outage.
- Running power — the station’s continuous rating is at least the total of everything running at once (all running watts added, a cautious assumption).
- Start-up surge — the station’s surge rating is at least everything running at once plus the largest extra start-up spike of any one appliance (its surge watts minus its running watts). If either side is unknown, the station can’t be marked as passing; it shows as “Check the surge.”
Boost modes (EcoFlow X-Boost, BLUETTI Power Lifting) run some heating appliances at reduced power. They are never used as a surge rating. Anker’s SurgePad is its name for the C1000’s actual surge capability.
Verdicts
- Covers it — passes all three checks, and lasts the outage even on the cautious efficiency case.
- Only just — passes on the expected case but not the cautious one.
- Check the surge — passes energy and running power, but a surge figure is unknown (usually an appliance you added without start-up watts).
- Short alone — needs its add-on battery — fails only on energy, and would pass at the maker’s maximum documented expansion, with the same output and surge. We only count expansion batteries the maker lists as available.
- Runs out early — fails on energy, with no expansion that fixes it.
- Can’t run this load — fails on running power or surge.
- Can’t power this — needs 240V or hardwired — an appliance in the list needs a 240V or hardwired supply. Every station we cover outputs 120V AC only, so no battery size fixes it; that is a wiring limit, not an energy limit.
- Check the connection — an appliance you added has an unconfirmed connection type. Like an unknown surge, an unverified check can’t earn a passing verdict.
For medical equipment, passing verdicts are relabeled “Estimate covers it — test first.” Discontinued stations are left out of planner results. Results are ordered by verdict, then smallest-that-works first. Whether a brand has an affiliate program plays no part, and we have no affiliate links.
Appliance figures
| Appliance | Running | Duty | Surge | Connects | Basis |
|---|---|---|---|---|---|
| Refrigerator | 150 W | 40% | 800 W | Standard 120V plug | Representative full-size fridge: 150W while the compressor runs, running about 40% of the time (about 1.4 kWh a day). Real fridges range widely; enter the yearly kWh from your yellow EnergyGuide label for a better figure. The 800W start-up surge is a conservative estimate, not a measurement. |
| Chest freezer | 100 W | 30% | unknown | Standard 120V plug | ENERGY STAR certified chest freezers (US DOE test procedure) use 201-277 kWh a year - Whirlpool 9.0 cu ft at 201 kWh/yr, Danby 10.0 cu ft at 211, GE 15.7 cu ft at 277 - an average draw of about 23-32W. This preset pairs a 100W compressor draw with a 30% duty cycle to reproduce that average (about 0.72 kWh a day). Neither ENERGY STAR nor DOE publishes a start-up surge for these models, so surge is left unset and the planner asks you to check it. |
| Wi-Fi router | 10 W | 100% | 15 W | Standard 120V plug | Typical home router about 10W. A separate modem adds a similar amount; check the watts or volts × amps on each power adapter. |
| Lights | 40 W | 100% | 40 W | Standard 120V plug | Four LED bulbs at about 10W each (an 800-lumen LED bulb uses about 9W, per the FTC). |
| Phone charging | 15 W | 50% | 15 W | Standard 120V plug | About 15W while charging, charging about half the time. Fast chargers can briefly draw more. |
| Laptop | 65 W | 60% | 90 W | Standard 120V plug | A 65W charger, drawing its full rating about 60% of the time on average (less while idle, more while charging). |
| TV | 110 W | 100% | 150 W | Standard 120V plug | A 55-inch LED TV uses about 100–120W (one ENERGY STAR-certified 55-inch model lists 106W on-mode). |
| Fan | 50 W | 100% | 75 W | Standard 120V plug | A box fan on medium is about 50W; window fans range up to a few hundred watts. |
| CPAP | 40 W | 100% | 90 W | Standard 120V plug | Conservative 40W with a heated humidifier and heated tube. ResMed publishes an average of about 34W for the AirSense 10 with humidifier and heated tube, about 22W with the humidifier only, and about 7W with neither. Your machine and pressure setting change this. |
| Space heater | 1500 W | 50% | 1500 W | Standard 120V plug | Most US plug-in space heaters draw 1,500W on high. Shown so you can see what a high-draw appliance does to a battery. |
Connection check (added Oct 12, 2026)
Portable stations output 120V AC — the voltage of a standard US wall outlet. Some home loads don’t plug into one: many well pumps, electric ovens and dryers, and larger air conditioners need 240V, and some equipment is hardwired with no plug at all. Watts alone can’t see this: a 240V pump can look easy for a big station on paper while no 120V outlet can ever run it. So every appliance and everything you add carries a connection type, and a 240V or hardwired selection means no station is ever recommended for that load: a station that passes the energy and power checks is marked “can’t power this,” and one that also fails on energy or power names that failure instead — the load is never shown as runnable either way. We never guess a connection type: “not sure” is treated as unverified, the same rule we apply to unknown surge figures. Loads like these belong on a properly installed transfer switch or interlock fed by a 240V-capable source, fitted by a licensed electrician — never on an improvised backfeed.
Product evidence rules
- Specs come from the manufacturer’s US product page or user manual. Where those aren’t available, we use the manufacturer’s other regional sites or a manual hosted by a third party, and say so on the station’s page.
- Where official sources disagree on a figure that affects a verdict, we use the more cautious one and explain the conflict (for example, the BLUETTI AC200L’s surge).
- Unknown is shown as unknown. We never fill a gap with a guess or with a boost-mode number.
- We record availability and warranty as stated on the manufacturer’s US site on the check date. We don’t show prices.
- We have not hands-on tested any station. Where independent tests exist, we cite them as independent tests, not as our own.
Solar and expansion views
These are shown in a station’s details but never change its verdict. Solar: daily energy ≈ the smaller of your panel watts and the station’s solar input limit × good sun hours × 0.75 (covering heat, angle, wiring and controller losses — an estimate; NREL’s PVWatts tool uses a 14% default system loss before other factors). Expansion: we re-run the energy check at the maximum capacity the maker documents.
Corrections log
- Oct 12, 2026 — BLUETTI AC180 surge: changed from unknown to 2,700W after confirming “Surge Power: 2700W” in BLUETTI’s US spec table and “can handle a surge of 2700W” in the user manual.
- Oct 12, 2026 — BLUETTI AC200L surge: BLUETTI’s US page says 4,800W, but the manual’s overload protection trips above 3,600W. We use 3,600W.
- Oct 12, 2026 — BLUETTI EB3A: marked discontinued (per BLUETTI US); removed from planner results.
- Oct 12, 2026 — CPAP default: lowered from 60W to 40W, based on ResMed’s published average of about 34W with heated humidifier and tube.
- Oct 12, 2026 — efficiency: replaced a fixed 85% with the load-aware model above, after independent tests showed much lower delivered energy at small loads.
- Oct 12, 2026 — Anker SOLIX C1000 expansion: earlier checks found the BP1000 expansion battery listed as “coming soon,” and the planner treated the C1000 as not expandable. Rechecked Oct 12, 2026: Anker’s US storefronts disagree (us.ankersolix.com says sold out; ankersolix.com shows an add-to-cart button). Under our conflicting-sources rule the planner still doesn’t count the C1000’s expansion; the spec tables show the 2,112Wh ceiling with that caveat.
- Oct 12, 2026 — ALLPOWERS R1500 expansion and warranty: ALLPOWERS’ own documents have disagreed (a lineup guide called the R1500 non-expandable; warranty figures vary). Its US product page states expansion to 4,608Wh with three B1000 batteries and a 5-year warranty; we follow the US product page and disclose the conflict on the R1500 page.
- Oct 12, 2026 — connection check and chest freezer: added the 240V/hardwired connection gate described above, and a chest-freezer preset (100W running, 30% duty) derived from ENERGY STAR certified chest-freezer energy use of 201–277 kWh a year; no published surge figure exists for the class, so its surge is shown as unknown.
- Oct 12, 2026 — surge check: fixed how start-up spikes combine. The old rule took the appliance with the highest surge watts plus everyone else’s running watts, which could understate the peak when a high-draw appliance like a heater was on alongside a fridge. It now adds the largest extra start-up spike to everything running.
Found an error? Email hello@whatstayson.com with the page and, ideally, the manufacturer source. See how corrections work.