Backing up a CPAP with a power station

Read this first. No calculator, including ours, can guarantee power for equipment you depend on for your health. Use these numbers to shortlist a station, confirm with your CPAP and station makers, talk to your care provider, and test a full night at home while the grid is still there to fall back on. If your therapy is life-sustaining, plan with your provider for more than one backup.

Short answer: with a heated humidifier and heated tube, a CPAP like the ResMed AirSense 10 averages about 34W; without them, about 7W. We plan with a cautious 40W, so one 8-hour night needs about 320Wh, and you should look for at least 510Wh on the box. Every in-stock station we cover clears that. The decisions that matter more are the humidifier, AC versus DC, and testing.

What a CPAP actually draws

ResMed publishes average power figures for its AirSense 10 machines. They show how much the comfort features dominate:

ResMed AirSense 10 AutoSet average draw (ResMed’s published figures)
SetupAverage draw8-hour night
CPAP onlyabout 7 Wabout 56 Wh
With heated humidifierabout 22 Wabout 176 Wh
With humidifier and heated tubeabout 34 Wabout 272 Wh

Pressure setting, room temperature and humidity change these numbers, and other machines differ (we couldn’t find comparable published figures for Philips DreamStation units). Check your machine’s manual, or measure it with a plug-in watt meter for a full night.

Turning the humidifier and heated tube off cuts the draw by about 70–80%, but that’s a therapy decision — ask your care provider before changing settings.

Why DC can matter more than battery size

A power station’s AC outlets run through an inverter, and the inverter uses power just to stay on. With a big load that overhead hardly matters; with a 7–10W CPAP it can use more energy than the CPAP itself. Independent tests published by Outdoor Life found stations delivered only 49–77% of their rated capacity at about 34W, compared with 76–92% at 380W.

On our estimates, a 10W CPAP through AC outlets needs a station with about 210Wh for one night. The same CPAP powered from the station’s DC output needs only about 120Wh, because there’s no inverter in the way. That saving depends on the inverter being off: if a fridge or anything else is running from the AC outlets overnight, the inverter is on anyway and DC saves little.

Switchover: will the CPAP keep running when the power cuts?

If the CPAP is plugged into the station while the station is plugged into the wall, most stations switch to battery when the grid fails. How fast varies:

Published switchover times (manufacturer-stated)
StationSwitchover
ALLPOWERS R150015 ms
BLUETTI AC180, AC200L20 ms
Jackery Explorer 1000 v2, Anker SOLIX C1000under 20 ms
EcoFlow DELTA 2, DELTA 2 Max, RIVER 2 Proup to 30 ms (EcoFlow calls it EPS, not 0 ms UPS)

These are manufacturer claims. Whether your particular CPAP rides through a 20–30 ms gap without restarting is something only a test will tell you — unplug the station from the wall while the CPAP is running (awake, not asleep) and watch what happens.

How big a station, honestly

Rehearse before you need it

  1. Charge the station fully.
  2. Set the CPAP exactly as you sleep with it — same pressure, humidifier and tube settings.
  3. Run a whole night from the station at home, with the grid available as backup.
  4. In the morning, note the battery percentage left. If it’s under about 30%, size up or change your setup.
  5. Repeat whenever you change settings, the machine, or the station — and once a season, since batteries age.

Other things to arrange

Try your own setup in the planner, set up for a CPAP overnight — tick “without the heated humidifier” if that’s how you sleep, and under “Fine-tune” tick “Run small devices from DC/USB ports” to see the difference.

Sources